Performance Based Plastic Design Of Concentrically Braced Frame Attuned With Indian Standard Code And Its Seismic Performance Evaluation

Authors : Purvang Dalal Sejal . Dhaval Patoliya . Dalal P D .

Abstract

In the Performance Based Plastic design method, the failure is predetermined; making it famous throughout the world. But due to lack of proper guidelines and simple stepwise methodology, it is not quite popular in India. In this paper, stepwise design procedure of Performance Based Plastic Design of Concentrically Braced frame attuned with the Indian Standard code has been presented. The comparative seismic performance evaluation of a six storey concentrically braced frame designed using the displacement based Performance Based Plastic Design (PBPD) method and currently used force based Limit State Design (LSD) method has also been carried out by nonlinear static pushover analysis and time history analysis under three different ground motions. Results show that Performance Based Plastic Design method is superior to the current design in terms of displacement and acceleration response. Also total collapse of the frame is prevented in the PBPD frame.

Keywords

Concentrically Braced Frames; Limit State Design Method; Performance Based Plastic Design Method; Target and Yield Mechanism